.. _headlabel-refx-record-79: 79H (Internal Temperature Alarm) ================================ This message can be sent to the backend server when an internal temperature alarm event is detected. For the internal temperature alarm event detection, please refer to :ref:`AT@ITMP ` command. The frame format of a report that only carries **79H** record is as follows: .. code-block:: none For example (Total 40 bytes): 2B 00 00 28 00 01 23 45 67 89 01 23 45 C0 31 00 0A 00 00 11 66 8E 47 F7 00 00 79 02 79 06 01 90 5D D5 2E FA 01 23 6C 24 .. tabularcolumns:: |p{3.8em}|p{3.2em}|p{5.5em}|p{5.8em}|p{15em}|p{4.8em}| .. table:: :width: 100% :widths: auto +----------+--------------------+------------------+---------------+------------------------------------------------+---------------+ | Parts | Fields | Length (Byte) | Range/Format | Default | +==========+====================+==================+===============+================================================+===============+ | Head | | 18 or 20 | | | +----------+--------------------+------------------+---------------+------------------------------------------------+---------------+ | Reserved | | 1 or 1+N | | | +----------+--------------------+------------------+---------------+------------------------------------------------+---------------+ | Records | Record Length | 1 or 2 | 00H-7FH or 8080H-FFFFH | | + +--------------------+------------------+---------------+------------------------------------------------+---------------+ | | Generated Time | 4 | | | + +--------------------+------------------+---------------+------------------------------------------------+---------------+ | | Record Count Number | 2 | 0000H-FFFFH | | + +--------------------+------------------+---------------+------------------------------------------------+---------------+ | | `Record ID` | 1 | **79H** | **79H** | + +--------------------+------------------+---------------+------------------------------------------------+---------------+ | | `Event Code` | 1 | 00H, 01H, 02H | | + +--------------------+------------------+---------------+------------------------------------------------+---------------+ | | `Data of Record` | Data ID | 1 or 2 | 00H-7FH or 8080H-FFFFH | | + + +------------------+---------------+------------------------------------------------+---------------+ | | | Data Length | 1 or 2 | 00H-7FH or 8080H-FFFFH | | + + +------------------+---------------+------------------------------------------------+---------------+ | | | Data Content | N | | | + + +------------------+---------------+------------------------------------------------+---------------+ | | | ... | | | | + +--------------------+------------------+---------------+------------------------------------------------+---------------+ | | ... | | | | +----------+--------------------+------------------+---------------+------------------------------------------------+---------------+ | Tail | | 4 | | | +----------+--------------------+------------------+---------------+------------------------------------------------+---------------+ The definitions of parts 'Head', 'Reserved', and 'Tail' are :ref:`here `. - `Event Code` - **00H** - Intenal temperature returns to normal. - **01H** - Internal temperature is low. - **02H** - Internal temperature is high. - `Data of Record` It consists of one or more :ref:`Data ID units `. By default, this record contains only the data IDs listed below, which can be changed by the `AT@QRC` command described below. - :ref:`Data 121 ` - Internal Temperature. .. configuration: Configuration ------------- The parameters related to the generation and transmission of **79H** record are controlled by the following :ref:`QRC ` command: .. code-block:: none Example: AT@QRC=gl601###,79,,,1,2|88,012F$ +ACK:QRC,123456789012345,C031,10,0,79,012F,20210407101530,1234$ AT@QRC?gl601###,79,0C37$ +QRY:QRC,123456789012345,C031,10,0,1,1,79,,,1,2|88,0C37,20210407101530,1234$ .. tabularcolumns:: |p{2.2em}|p{14.2em}|p{5.8em}|p{12em}|p{4.8em}| .. table:: :width: 100% :widths: auto +-------+-----------------------+---------------+------------------------------------------------+----------------+ | Parts | Fields | Length (Byte) | Range/Format | Default | +=======+=======================+===============+================================================+================+ | Head | Header | 3 | AT@ | AT@ | + +-----------------------+---------------+------------------------------------------------+----------------+ | | Command Word | 3 | QRC | QRC | + +-----------------------+---------------+------------------------------------------------+----------------+ | | Leading Symbol | 1 | = | = | + +-----------------------+---------------+------------------------------------------------+----------------+ | | Password | 8-16 | | gl601### | +-------+-----------------------+---------------+------------------------------------------------+----------------+ | Body | `Record ID` | 2 | 79 | 79 | + +-----------------------+---------------+------------------------------------------------+----------------+ | | Reserved | 0 | | | + +-----------------------+---------------+------------------------------------------------+----------------+ | | Reserved | 0 | | | + +-----------------------+---------------+------------------------------------------------+----------------+ | | `Action` | 1 | 0-2 | | + +-----------------------+---------------+------------------------------------------------+----------------+ | | `Data IDs` | N | ID1|ID2|ID3… | | +-------+-----------------------+---------------+------------------------------------------------+----------------+ | Tail | Sequence Number | 4 | 0000-FFFF ('0'-'9', 'A'-'F') | | + +-----------------------+---------------+------------------------------------------------+----------------+ | | Tail | 1 | $ | $ | +-------+-----------------------+---------------+------------------------------------------------+----------------+ - `Record ID` Which record to configure. Always "79" here. - `Action` - **Empty** - No change the data IDs in the terminal. If this field is empty, the 'Data IDs' field will be ignored. - **0** - Append the data IDs carried in the 'Data IDs' field to the terminal. - **1** - Replace the data IDs in the terminal with the data IDs carried by the 'Data IDs' field. - **2** - Clear the data IDs carried in the 'Data IDs' field from the terminal. **Note**: In particular, it always will be 1 when reading this field. - `Data IDs` The data IDs contained in the 79H record. The characters '|' are used to connect each data ID. For example, "2|88" means Data 2 (Device Name) and Data 88 (SIM Card).