Data 125 (Tamper Status)

Identifies the status information of the tamper.

The frame format of the Data 125 unit is as follows:

For example (Total 8 bytes):
7D 06 00 01 00 00 01 2C

Parts

Fields

Length (Byte)

Range/Format

Default

ID

Data ID

1

7DH (125)

7DH (125)

Length

Data Length

1

00H or 06H

Content

Current Status

1

00H, 01H, FFH

Previous Status

1

00H, 01H, FFH

Previous Status Duration

4

00000000H-FFFFFFFFH (seconds)

  • Current Status

    The current status of the tamper alarm detection.

    • 00H - Normal.

    • 01H - Tamper alarm.

    • FFH - Unknown.

  • Previous Status

    The previous status of the tamper alarm detection.

    • 00H - Normal.

    • 01H - Tamper alarm.

    • FFH - Unknown.

  • Previous Status Duration

    Indicates how long the ‘Previous Status’ remains. Expressed as a 32-bit unsigned integer and the unit is second. In particular, FFFFFFFFH means invalid value.