Data 26 (Tow Status)¶
The frame format of the Data 26 unit is as follows:
For example (Total 3 bytes):
1A 01 00
Parts |
Fields |
Length (Byte) |
Range/Format |
Default |
|---|---|---|---|---|
ID |
Data ID |
1 |
1AH (26) |
1AH (26) |
Length |
Data Length |
1 |
00H or 01H |
|
Content |
Tow Status |
1 |
00H, 01H, 02H |
Tow Status
The vehicle’s current tow status.
00H - The vehicle is not being towed now.
01H - Fake Tow. The vehicle is ignition off and it is likely to be being towed now.
02H - Tow. The vehicle is being towed now.