Data 97 (Internal Battery Status)ΒΆ

The current status of the internal battery.

The frame format of the Data 97 unit is as follows:

For example (Total 7 bytes):
61 05 01 0D 20 00 00

Parts

Fields

Length (Byte)

Range/Format

Default

ID

Data ID

1

61H (97)

61H (97)

Length

Data Length

1

00H or 05H

Content

Basic Status

1

00H-FFH

Voltage

2

0000H-FFFFH (mV)

Reserved

1

00H-FFH

00H

Charging

1

00H-FFH

  • Basic Status

    The lowest two bits are used to indicate the connection status and disabled state, while the other bits are reserved and default to 0.

    • Connection Status (Bit0)

      Indicates whether the internal battery is connected.

      • 0b0 - Not connected.

      • 0b1 - Connected.

    • Disabled Status (Bit1)

      Indicates whether the internal battery is disabled.

      • 0b0 - No.

      • 0b1 - Yes.

  • Voltage

    The internal battery voltage of the terminal device. Expressed as a 16-bit unsigned integer and the unit is mV. This field is only valid when Connection Status is 01H (Connected).

  • Charging

    Whether the internal battery is being charged. For non-rechargeable battery, the value of this field is 02H.

    • 00H - Not charging.

    • 01H - Charging.

    • 02H - Not support.