Data 98 (Idling Status)¶
Idling status means that the vehicle is ignition on but not driving.
Please refer to AT@IDLE command for more information.
The frame format of the Data 98 unit is as follows:
For example (Total 7 bytes):
62 05 01 00 00 00 B4
Parts |
Fields |
Length (Byte) |
Range/Format |
Default |
|---|---|---|---|---|
ID |
Data ID |
1 |
62H (98) |
62H (98) |
Length |
Data Length |
1 |
00H or 05H |
|
Content |
Idling Status |
1 |
00H, 01H, 02H |
|
Idling Duration |
4 |
00000000H-FFFFFFFFH (seconds) |
Idling Status
The vehicle’s current idling status.
00H - The vehicle is not idling.
01H - The vehicle is idling.
02H - Unknown.
Idling Duration
Duration of idling status. Expressed as a 32-bit unsigned integer and the unit is second.
Each time the vehicle enters the idling status, it is cleared and then recalculated.