Data 98 (Idling Status)

Idling status means that the vehicle is ignition on but not driving.

Please refer to AT@IDLE command for more information.

The frame format of the Data 98 unit is as follows:

For example (Total 7 bytes):
62 05 01 00 00 00 B4

Parts

Fields

Length (Byte)

Range/Format

Default

ID

Data ID

1

62H (98)

62H (98)

Length

Data Length

1

00H or 05H

Content

Idling Status

1

00H, 01H, 02H

Idling Duration

4

00000000H-FFFFFFFFH (seconds)

  • Idling Status

    The vehicle’s current idling status.

    • 00H - The vehicle is not idling.

    • 01H - The vehicle is idling.

    • 02H - Unknown.

  • Idling Duration

    Duration of idling status. Expressed as a 32-bit unsigned integer and the unit is second.