Data 87 (External Power Voltage)

The basic information of the external power supply.

The frame format of the Data 87 unit is as follows:

For example (Total 5 bytes):
57 03 01 2E E0

Parts

Fields

Length (Byte)

Range/Format

Default

ID

Data ID

1

57H (87)

57H (87)

Length

Data Length

1

00H or 03H

Content

Connection Status

1

00H-01H

Voltage

2

0000H-FFFFH (mV)

  • Connection Status

    Whether the external power supply is connected.

    • 00H - Not connected.

    • 01H - Connected.

  • Voltage

    The external power supply voltage of the terminal device. Expressed as a 16-bit unsigned integer and the unit is mV. The field indicates the exact current voltage vlaue only when ‘Connection Status’ is 01H (Connected). If the ‘Connection Status’ is 00H (Not connected), then the value of this field is normally 0000H, FFFFH, or the last voltage value read.